FT-950

Operating Manual

Menu Mode

The Menu system of the FT-950 provides extensive customization capability, so you can set up your transceiver just the way you want to operate it. The Menu items are grouped by general utilization category, and are numbered from “001 AGC FST DLY” to “118 TGEN EMRGNCY”.

Using the Menu

1.Press the [MENU] button momentarily, to engage the Menu mode.

The display will show the Menu Number, Menu Group Name, and Menu Item. Press the [SELECT] knob to toggle the display between “Menu Number & Menu Group Name” and “Menu Item”. The Multi-Display Window shows the current setting of the currently-selected Menu item.

2.Rotate the [SELECT] knob to select the Menu item you wish to work on.

3.Rotate the [CLAR/VFO-B] knob to change the current setting of the selected Menu item.

4.When you have finished making your adjustments, press and hold in the [MENU] button for two seconds to save the new setting and exit to normal operation. If you only momentarily press the [MENU] button, the new settings will not be retained.

Menu Mode Reset

You may reset all the Menu settings to their original factory defaults, if desired.

1.Turn the front panel [POWER] switch off.

2.Press and hold in the [MENU] button, and while holding it in, press the [POWER] switch to turn the transceiver back on. Now release the [MENU] button.

AGC Group

001 AGC FST DLY

Function: Sets the delay time for the AGC FAST mode.

Available Values: 20 ~ 4000 msec (20 msec/step)

Default Setting: 300 msec

002 AGC MID DLY

Function: Sets the delay time for the AGC MID mode.

Available Values: 20 ~ 4000 msec (20 msec/step)

Default Setting: 700 msec