022 KEY CW MEM4
Function: Permits entry of the CW message for message register 4.
Available Values: tyP1/tyP2
Default Setting: tyP2
tyP1: You may enter the CW message from the Main Tuning Dial knob and
tyP2: You may enter the CW message from the CW keyer.
023 KEY CW MEM5
Function: Permits entry of the CW message for message register 5.
Available Values: tyP1/tyP2
Default Setting: tyP2
tyP1: You may enter the CW message from the Main Tuning Dial knob and
tyP2: You may enter the CW message from the CW keyer.
GENERAL Group
024 GENE ANT SEL
Function: Sets the method of antenna selection.
Available Values: bAnd/rEG
Default Setting: bAnd
bAnd: The antenna is selected in accordance with the operating band.
rEG: The antenna is selected in accordance with the band stack (different antennas may be utilized on the same band, if so selected in the band stack).
025 GENE BEP LVL Function: Sets the beep level. Available Values: 0 ~ 100 Default Setting: 50
026 GENE CAT BPS
Function: Sets the transceiver’s
Available Values: 4800/9600/384H (38400) bps
Default Setting: 4800 bps