FT-950
Operating Manual
13. [METER] Switch
This button determines the function of the meter during transmission.
Press this button to change the meter function in the transmit mode as follows:
ALC SWR | ID VDD COMP ALC …… |
ALC: | Indicates the relative ALC voltage. |
SWR: | Indicates the Standing Wave Ratio (Forward: Reflected). |
ID: | Indicates the final amplifier drain current. |
VDD: | Indicates the final amplifier drain voltage. |
COMP: | Indicates the speech compressor level (SSB modes only). |
14. [MIC GAIN] Knob
This knob adjusts the microphone input level for
Advice: If you adjust the [MIC GAIN] knob while speaking in a somewhat louder than normal voice level, watch the ALC level and adjust the [MIC GAIN] knob so that the ALC reaches just to the right edge of the ALC scale. Then, when you speak in a more normal voice level, you’ll be certain not to be
15. [SPEED] Knob
This knob adjusts the keying speed of the internal CW keyer (4 ~ 60 WPM). Clockwise rotation increases the sending speed.
When turning this knob while pressing the [KEYER] button, the frequency display shows the keying speed.
16. Microphone Connector
This
17. KEY Jack
This
18 | Vertex Standard Co., Ltd. |