Available Values: OFF/0.5/1.0/2.0 sec

Default Setting: OFF

008 DISP PKH PO

Function: Selects the peak hold time of the PO meter.

Available Values: OFF/0.5/1.0/2.0 sec

Default Setting: OFF

009 DISP PKH ALC

Function: Selects the peak hold time of the ALC meter.

Available Values: OFF/0.5/1.0/2.0 sec

Default Setting: OFF

010 DISP PKH ID

Function: Selects the peak hold time of the ID meter.

Available Values: OFF/0.5/1.0/2.0 sec

Default Setting: OFF

011 DISP RTR STU

Function: Selects the starting point of your rotator controller’s indicator needle.

Available Values: 0/90/180/270°

Default Setting: 0°

Advice: If the optional DMU-2000 Data Management Unit is not connected, this adjustment has no effect.

012 DISP RTR ADJ

Function: Adjusts the indicator needle precisely to the starting point set in menu item “011 DISP RTR STU.”

Available Values: –30 ~ 0

Default Setting: 0

Advice: If the optional DMU-2000 Data Management Unit is not connected, this adjustment has no effect.

013 DISP QMB MKR

Function: Enables/Disables the QMB Marker (White arrow “V”) to display on the Spectrum Band Scope when the optional DMU-2000 Data Management Unit is