into the ground. If multiple ground rods are used, they should be positioned in a “V” configuration, and bonded together at the apex of the “V” which is nearest the station location. Use a heavy, braided cable (such as the discarded shield from type
Inside the station, a common ground bus consisting of a copper pipe of at least 25 mm (1”) diameter should be used. An alternative station ground bus may consist of a wide copper plate
Do not make ground connections from one electrical device to another, and thence to the ground bus. This
Inspect the ground
Besides following the above guidelines carefully, note that household or industrial gas lines must never be used in an attempt to establish an electrical ground. Cold water pipes may, in some instances, help in the grounding effort, but gas lines represent a significant explosion hazard, and must never be used.
Connection of Antenna and Power Cables
Please follow the outline in the illustration regarding the proper connection of antenna coaxial cables, as well as the DC power cable.
Use a short, thick, braided cable to connect your station equipment to the buried ground rod (or alternative earth ground system).
Advice:
Do not position this apparatus in a location with direct exposure to sunshine.
Do not position this apparatus in a location exposed to dust and/or high humidity. Ensure adequate ventilation around this apparatus, so as to prevent heat
12 | Vertex Standard Co., Ltd. |