FT-950

Operating Manual

Advice: If you do not find the Menu item number, press the [SELECT] knob momentarily to switch the Menu item name to the Menu item number.

7.Rotate the [CLAR/VFO-B] knob to perform adjustments to a particular Menu item.

8.Close the PTT switch, and speak into the microphone while listening to the effects of the changes you are making. Because the overall effect on the sound will change with each adjustment you make, you should make several passes through each adjustment area, to be sure that you are achieving the optimum setting.

9.When you have completed all adjustments, press and hold in the [MENU] button for two seconds to save the new settings and exit to normal operation. If you only press the [MENU] button momentarily to exit, any changes you performed will not be stored.

Advice: To roll off excessive bass response in a wide-range studio microphone, try putting a 10 dB null at 100 Hz with a bandwidth of “1” or “2”, do about a 3 dB null centered on 800 Hz with a bandwidth of “3,” and then put an 8 dB peak centered on 2100 Hz with a bandwidth of “1.” These are starting recommendations; each microphone and user’s voice will be different, often requiring different settings.

Activating the Parametric Microphone Equalizer

1.Adjust the [MIC GAIN] knob for SSB use, as described on page ??.

2.Press the [PROC] button momentarily. The “MIC EQ” icon will appear in the display, confirming that the Parametric Microphone Equalizer is engaged.

Advice

A blinking “MIC ICON” icon indicates the Parametric Microphone Equalizer menu settings have all been set to “OFF” (“091 TAUD EQ1 FRQ”, “094 TAUD EQ2 FRQ”, “097 TAUD EQ3 FRQ”.

3.Press the PTT switch on the microphone, and speak into the microphone in a normal voice level.

4.To switch the Parametric Microphone Equalizer off, press the [PROC] button repeatedly until the “MIC EQ” icon disappears.

3-Stage Parametric Equalizer Adjustments (Speech Processor: “OFF”)

Center Frequency

 

 

“091 TAUD EQ1 FRQ”

“100” (Hz) ~ “700” (Hz)

 

“094 TAUD EQ2 FRQ”

“700” (Hz) ~ “1500” (Hz)

 

“097 TAUD EQ3 FRQ”

“1500” (Hz) ~ “3200” (Hz)

 

 

66

Vertex Standard Co., Ltd.

Page 66
Image 66
Vertex Standard manual FT-950 Operating Manual