XES Synergix 8825/8830/8850/8855 Digital Solution User Guide

96

Main Menu (continued)

IMAGE PATH

Select the IMAGE PATH option to validate the operation of the image processing (IP) card and the image bar.

To run the IMAGE PATH diagnostic:

1.Press the Menu key. The MAIN MENU screen is displayed.

2.Press the Next key until DIAGNOSTICS is highlighted.

3.Press the Enter key to select DIAGNOSTICS. The DIAGNOSTICS menu screen is displayed.

4.Press the Next key until SCANNER DIAGNOSTICS is displayed.

5.Press the Enter key to select SCANNER DIAGNOSTICS. The SCANNER DIAGNOSTICS menu screen is displayed.

6.Press the Enter key to select IMAGE PATH. The IMAGE PATH screen is displayed.

 

 

IMAGE PATH

BOARD ID: 2

STATUS: 0

BAR1:

0

BAR2: 0

BAR3:

0

ALL: 0

 

 

 

When you enter the IMAGE PATH screen, the status field for all tests contains a "0." After a few seconds, the results of the tests are displayed. A test result with no failure displays as PASS. A test result with a failure displays a failure code. If a failure code is displayed, call for service.

7.Press the Exit key to return to the SCANNER DIAGNOSTICS menu screen.

SCAN BAR

Select the SCAN BAR option to calibrate the response of the scan bar. To run the SCAN BAR diagnostic:

1.Press the Menu key. The MAIN MENU screen is displayed.

2.Press the Next key until DIAGNOSTICS is highlighted.

3.Press the Enter key to select DIAGNOSTICS. The DIAGNOSTICS menu screen is displayed.

4.Press the Next key until SCANNER DIAGNOSTICS is displayed.

5.Press the Enter key to select SCANNER DIAGNOSTICS. The SCANNER DIAGNOSTICS menu screen is displayed.

6.Press the Next key to highlight SCAN BAR.

7.Press the Enter key to select SCAN BAR. The SCAN BAR screen is displayed.

SCAN BAR

CALIBRATION TEST

PRESS START TO BEGIN

8.Press the Start key to begin the test. While the test is executing, the bottom display line changes to "RUNNING."

At the completion of the test, the test result is displayed. A test result with no failure displays as PASSED. A test result with a failure displays as FAILED followed by ERROR CODE: and a hexadecimal value between 0 and FF. If a failure code is displayed, call for service.

9.Press the Exit key to return to the SCANNER DIAGNOSTICS menu screen.

Page 106
Image 106
Xerox 8855, 8825, 8830 manual Board ID Status BAR1, BAR2, BAR3, All, Scan BAR Calibration Test Press Start to Begin