10.To check the status of the thick document sensor:

a.Raise the Thick Document Lever. The status of the sensor will change from NO to YES.

b.When finished viewing the status of the thick document sensor, lower the Thick Document Lever.

11.To check the status of HOME sensor.

a.Raise the Document Handler just enough to access the Calibration Roll drive gear and still be able to see the Display.

b.Rotate the Calibration Roll one full revolution, the status will change from NO to YES if the sensor is okay.

Calibration Roll

Drive Gear

12. Press the Exit key to return to the COMPONENT TESTS menu screen.