Product Description
The following options provide added protection:
Black fin condenser coils – Condenser coils constructed using black epoxy coated Aluminum fin stock for cor- rosion resistance comparable to copper fin coils in typical seashore locations.
Copper fin condenser coils – Coils constructed with corrosion resistant copper fins. Not recommended in areas where units may be exposed to acid rain.
Phenolic coated condenser coils – Completed con- denser coil assemblies are covered with a cured Phenolic coating. Probably the most suitable selection for sea- shore locations where salt spray may come into contact with the fins, and other corrosive applications except: strong alkalis, oxidizers, and wet bromine, chlorine, and fluorine in concentrations greater than 100 PPM.
DX EVAPORATOR AND STARTER OPTIONS
300 PSIG (21 bar) Waterside Design Working Pressure – The DX evaporator waterside is designed and constructed for 300 PSIG (21 bar) working pressure.
Flange Accessory – Consists of raised face flanges to convert grooved water nozzles to flanged evaporator connections. Includes companion flanges for field- mounting. (See Page 33.)
Remote DX Evaporator – Includes the main con- densing unit less the evaporator, refrigerant and liquid line devices. The insulated evaporator and field acces- sory kits per refrigerant circuit are supplied separately. The condensing unit is shipped with a nitrogen holding charge and the evaporator is shipped with a nitrogen holding charge.
Flow Switch Accessory – Johnson Controls model
FORM
UNIT ENCLOSURES OPTIONS
Wire enclosure – Heavy gauge welded wire mesh guards mounted on the exterior of the unit (Factory- or
Louvered panels and wired guards – Louvered pan- els mounted over the exterior condenser coil faces, and heavy gauge welded wire mesh guards mounted around the bottom of the unit (Factory- or
Louvered panels (condenser coils only) – Louvered panels are mounted over the exterior condenser coil faces on the sides of the unit to visually screen and protect the coils (Factory- or
Louvered panels (full unit) enclosure – Louvered panels over condenser coils and around the bottom of the unit (Factory- or
FAN OPTIONS
High static fans: Fans and motors suitable for High External Static conditions to 100 Pa.
SOUND REDUCTION OPTIONS
Low speed fans – Reduced RPM fan motors and alter- native fan selection for low noise applications.
Compressor sound enclosures – Acoustically treated metal compressor enclosures.
VIBRATION ISOLATION
Neoprene pad isolation – Recommended for normal installations.
1" (25 mm) spring isolators – Level adjustable, spring and cage type isolators for mounting under the unit base rails
2" (51 mm) seismic spring isolators – Restrained
24 | YORK INTERNATIONAL |