TABLE OF CONTENTS (CONT’D)
SECTION 8 - MICRO PANEL CONTENTS
CHILLERLER CONTROL PANEL |
| ||
PROGRAMMING AND DATA ACCESS KEYS | 122 | ||
DISPLAY AND STATUS INFORMATION KEYS .... | 122 | ||
ON / OFF ROCKER SWITCH | 122 | ||
PROGRAM & SETUP KEYS | 122 | ||
1. INTRODUCTION & PHYSICAL DESCRIPTION 123 | |||
1.1 | General | 123 | |
1.2 | Keypad & Display | 123 | |
1.3 | Unit (chiller) ON/OFF Switch | 124 | |
1.4 | Microprocessor Board | 124 | |
1.5 Ancillary Circuit Boards | 124 | ||
1.6 | Circuit Breakers | 125 | |
1.8 Transformers | 125 | ||
1.9 | Motor Protection Modules | 125 | |
1.10 | EMS/BAS Controls | 128 | |
1.11 Microprocessor Board Layout | 130 | ||
1.12 | Logic Section Layout | 131 | |
1.13 | 132 | ||
1.14 | 132 | ||
1.15 | Evaporator Pump Control | 132 | |
1.16 | Compressor Heater Control | 132 | |
1.17 | Evaporator Heater Control | 132 | |
1.18 | Pumpdown (EEV) Control | 132 | |
1.19 Alarms | 133 | ||
1.20 | Run Status (chiller) | 133 | |
1.21 | Lead / Lag Compressor Selection | 133 | |
1.22 | Economizer Solenoid Control | 134 | |
2. STATUS KEY: GENERAL STATUS MESSAGES & | |||
FAULT WARNINGS | 136 | ||
2.1 | General | 136 | |
2.2 | General Status Messages | 136 | |
2.3 | Unit Warnings | 137 | |
2.4 Anticipation Control Status | 138 | ||
2.5 | Unit Fault Status Messages | 139 | |
2.6 | System Fault (SAFETY) status | 140 | |
2.7 | Printout on Fault Shutdown | 143 | |
3. DISPLAY KEYS & OPTION SWITCHES | 144 | ||
3.1 | General | 144 | |
3.2 | Chilled Liquid Temps key | 144 | |
3.3 | System # Data Keys | 145 | |
3.4 Ambient Temp Key | 145 | ||
3.5 % Motor Current key | 146 |
3.6 | Operating Hrs / Start Counter key | 146 |
3.7 | Options key & | 146 |
3.8 | Funtion Key | 148 |
4. PRINT KEYS | 149 | |
4.1 | General | 149 |
4.2 | Oper Data Key | 149 |
4.3 | Operating Data – Software Version | 149 |
4.4 | Operating Data – Remote Printout | 151 |
4.5 | History Key | 152 |
4.6 | Fault History Data – Local Display |
|
| Messages | 152 |
4.7 | Fault History Data – Remote Printout | 156 |
5. ENTRY KEYS | 157 | |
5.1 | General | 157 |
5.2 | Numerical Keypad | 157 |
5.3 | Enter Key | 157 |
5.4 | Cancel Key | 157 |
5.5 | KEYS | 157 |
6. SETPOINTS KEYS & CHILLED LIQUID |
| |
CONTROL | 158 | |
6.1 | General | 158 |
6.2 | Chilled Liquid Temperature Control | 158 |
6.3 | Local Cooling Setpoints Key | 162 |
6.4 | Remote cooling setpoints Key | 162 |
7. CLOCK KEYS | 163 | |
7.1 GENERAL | 163 | |
7.2 SET TIME KEY | 163 | |
7.3 set schedule / holiday key | 164 | |
7.4 | Manual Override key | 165 |
8. PROGRAM KEY | 166 | |
8.1 | General | 166 |
8.2 | Program Key – User Programmable Value .. | 166 |
8.3 | Programming "Default" Values | 170 |
8.4 | Electronic Expansion Valve | 172 |
8.5 | EEV Operation | 173 |
8.6 EEV Programming | 175 | |
8.7 | EEV Troubleshooting | 176 |
8.8 | Condenser Fan Control | 177 |
8.9 | Service Mode: Unit Setup | 179 |
8.10 Sensor Calibration Charts | 185 | |
8.11 Control Inputs/Outputs | 186 | |
8.12 ISN Control | 189 |