ZyWALL 5/35/70 Series User’s Guide

The following table describes the fields in this menu.

Table 196 Menu 11.3.3: Remote Node Script

FIELD

DESCRIPTION

 

 

Active

Press [SPACE BAR] and then [ENTER] to select either Yes to enable the AT strings or

 

No to disable them.

Set 1-6:

Enter an Expect string to match. After matching the Expect string, the ZyWALL returns

Expect

the string in the Send field.

Set 1-6:

Enter a string to send out after the Expect string is matched.

Send

 

34.10 Remote Node Filter

Move the cursor to the field Edit Filter Sets in menu 11.3, and then press [SPACE BAR] to set the value to Yes. Press [ENTER] to open Menu 11.3.4 - Remote Node Filter.

Use menu 11.3.4 to specify the filter set(s) to apply to the incoming and outgoing traffic between this remote node and the ZyWALL to prevent certain packets from triggering calls. You can specify up to four filter sets separated by commas, for example, 1, 5, 9, 12, in each filter field. Note that spaces are accepted in this field. Please refer to Chapter 44 on page 580 for more information on defining the filters.

Figure 280 Menu 11.3.4: Remote Node Filter

Menu 11.3.4 - Remote Node Filter

Input Filter Sets: protocol filters= device filters= Output Filter Sets: protocol filters= device filters=

Call Filter Sets: protocol filters=

device filters=

Enter here to CONFIRM or ESC to CANCEL:

521

Chapter 34 WAN and Dial Backup Setup