The following example shows the usage of the JavaScript MULTI_SCREEN_ID variable to control the text content of a textArea item.

<spx:multiScreen>

<spx:screen viewBox="0 0 1280 720" xml:id="left"/> <spx:screen viewBox="0 0 1280 720" xml:id="right"/> </spx:multiScreen>

<script>

<![CDATA[

if (MULTI_SCREEN_ID == "left") document.getElementById("textId").textContent="I'm left!"; else if (MULTI_SCREEN_ID == "right") document.getElementById("textId").textContent="I'm right!"; else

document.getElementById("textId").textContent="No screen defined!"; ]]>

</script>

<g>

<text x="50" y="50" xml:id="textID">_Text_will_be_here_</text> </g>

Troubleshooting

Synchronized content over multiple screen needs a correct configuration of the IS-SPX Player and a well-designed project to work as expected. In the event that the project is not displaying as desired, the following is a list of parameters to check before contacting AMX Technical Support.

NTP Synchronization

The content are not synchronized, i.e. one or more screens play their part of media earlier or later than the other displays. Please check the following:

Make sure that NTP is enabled through the Browser-Based Configuration Pages, and that you have chosen one or more NTP servers:

It should be on your local network in order to be able to achieve the few milliseconds of precision required. Public NTP servers are usually too “far” to provide such a precision. Please refer to the Synchronization on page 52 for details on inserting NTP server addresses.

Verify your IS-SPX Players NTP statistics:

Values in the column “Time offset” should be as close to 0 as possible.

Make sure that at least one NTP server is always reachable (at least one column “Reach” should be equal to 100%).

In case your NTP server can't be reached (“Status” column remains always “Initializing”), it may be behind a firewall or

just wrongly configured. Check the NTP server configuration with your system administrator. For further details on the NTP protocol, please refer to http://www.ntp.org.

If you used the master/slave configuration, be careful to correctly implement the architectures covered in the Using an IS-SPX Player as an NTP Server on page 54. Double check your master ("Monitor only" selected) and slave

configurations ("Monitor only" NOT selected).

Project Creation

Verify that your index.svg file contains the spx:begin attribute, or that your project uses a schedule file (.ics), as explained in the Syntax for Multiscreen Synchronized Content on page 56. A good test to verify if your content uses a begin attribute or a calendar is to open the index.svg file in XPress. If your project starts from the beginning, then no

schedule is present.

If opening the project multiple times always shows the same starting point, then no schedule is present and the playback will not be synchronized.

Internal Clock Calibration

The local clock on the device is not calibrated when shipped from the factory. NTP behaves differently when the local clock has not yet been calibrated, and it will not synchronize as expected. Figure 20 below shows the configuration window before calibration is completed.