Connectivity

To Program PBX Ports

Procedure 4:

Use the following steps to program the following:

Data-only

A stand-alone 7400B data module that only carries data

data module

 

and ADU

An ADU

 

You may have to use modem pooling.

Step Action

1Enter the following command: add data-module

2Enter the following in the Type field:

For a data module, enter pdm

For an ADU, enter data-line

3Set the baud rate of the PBX or the AUDIX system to match the baud rate of Proxy Agent.

4For the ADU, set the Auto Adjust field to n.

End

See also

For more details, refer to the DEFINITY G3 product

 

documentation. For a complete list of DEFINITY documents, see

 

Related Resources in the About This Book.

6-14Issue 2 April 1996

Page 128
Image 128