Alarms

Program the Alarm Receiver Port

Procedure 5: The following Add Port Services to Port Monitor alrmrcvr screen

Enter port shows your field entries for page 2: services

data, page 2

Add Port Services to Port Monitor alrmrcvr

Page 2 of 2

Name of TTY device: /dev/tty00

ttylabel: 1200

Service command: /usr/bin/shserv

TTY line options:

Hangup: Yes Connect-on-carrier: No

Bidirectiona1: Yes Wait-Read: Yes

Timeout: O

Prompt message: login

(Optional fields)

Modules to be pushed: ldterm

If your serial port is not tty00, substitute the port’s name for the entry in the Name of TTY device field. When you finish, complete the following steps.

Step

Action

1Press F3 to save your work.

2Press F7 to access the Command menu.

3Select exit to return to the shell prompt.

End

10-8Issue 2 April 1996