Cabletron Systems EMM-E6 Ethernet manual Setting Default Gateway and Interface

Models: EMM-E6 Ethernet

1 205
Download 205 pages 30.59 Kb
Page 108
Image 108

SETTING DEFAULT GATEWAY AND INTERFACE

To set the Default Gateway and its associated Default Interface:

1.Use the arrow keys to highlight the Default Interface field.

2.Enter the interface number of the EMM-E6 for the Default Gateway in this field. The interface number will be a value between 1 and 6. A table of the interface numbers may be found in section 7.2.

NOTE

The EMM-E6 will not allow Local Management to configure the Default Interface to utilize an unsubscribed interface. For example: To select Interface 5 as the Default Interface, a BRIM module must first be configured to the E channel of the EMM-E6.

3.Press the Return key. If the EMM-E6 accepts your entry as a valid Default Interface, it displays “Previous Default Interface Marked Invalid” at the top of the screen.

4.Use the arrow keys to highlight the Default Gateway field.

5.Enter the gateway’s IP address in this field. The format for this entry is XXX.XXX.XXX.XXX with values for XXX ranging from 0 to 254.

6.Press the Return key. If the EMM-E6 accepts your entry as a valid Default Interface, it displays “Previous Default Interface Marked Invalid” at the top of the screen.

You have now established a Default Gateway and Default Interface for your EMM-E6.

EMM-E6 User’s Guide

7-7

Page 108
Image 108
Cabletron Systems EMM-E6 Ethernet manual Setting Default Gateway and Interface