Cabletron Systems EMM-E6 Ethernet manual Connecting an AUI Cable to an EPIM-X, The EPIM-X

Models: EMM-E6 Ethernet

1 205
Download 205 pages 30.59 Kb
Page 82
Image 82

CONNECTING TO THE NETWORK

3.9.2Connecting an AUI Cable to an EPIM-X

NOTE

The Signal Quality Error (SQE) switch remains in the OFF position for most network connections. However, some Data Terminal Equipment (DTE) requires SQE. Refer to your DTE manual for SQE requirement information.

To connect an EPIM-X to a device not requiring SQE:

1.Verify that the SQE LED on the EPIM-X is off. If the SQE LED is on, set the position of the SQE switch to off.

NOTE

If the SQE light remains on, even though the SQE switch is in the OFF position, contact Cabletron Technical Support.

2.Attach one end of an AUI cable, no longer than 50 meters in length, to the port located on the EPIM-X (Figure 3-12) and the other end to the intended node.

ON Position

 

ON

(Toward Back

 

of EPIM)

 

OFF Position

(Toward Front

of EPIM)

OFF

Figure 3-12. The EPIM-X

EMM-E6 User’s Guide

3-21

Page 82
Image 82
Cabletron Systems EMM-E6 Ethernet manual Connecting an AUI Cable to an EPIM-X, The EPIM-X