CHAPTER 14: TROUBLESHOOTING

Table 14-1. LANVIEW LEDs

LED

Color

Description

Error Condition/

Recommended Action

 

 

 

 

 

 

 

CPU

Multicolor

Flashing Green

If OFF, or Red, the board has a

 

 

indicates that the

problem.

 

Green

board is

 

 

Red

operating

Press the reset switch on the

 

 

properly.

EMM-E6 front panel to re-

 

 

 

initialize the board. If the board

 

 

 

does not re-initialize, it has

 

 

 

probably failed. Call Cabletron

 

 

 

Technical Support.

 

 

 

 

STBY

Yellow

Indicates

Network Management has

A,B,C,D

 

packets will not

placed the EMM-E6 in a

(Standby)

 

be forwarded as

Standby condition; a data loop

 

 

the Spanning

condition exists.

 

 

Tree Algorithm

 

 

 

has put the

Check with your Network

 

 

corresponding

Administrator to find out if the

 

 

Bridge Port into

EMM-E6 was placed in

 

 

a standby mode

Standby on purpose.

 

 

due to detecting

 

 

 

a data loop

If a Data loop does exist,

 

 

condition.

reconfigure the network to

 

 

 

remove the data loop.

 

 

 

 

RCV

Yellow

LED flashes to

If none of the receive LEDs is

A,B,C,D

 

indicate that a

flashing, the EMM-E6 is not

(Receive)

 

segment is

receiving frames on any of the

 

 

receiving a

segments.

 

 

frame.

 

 

 

 

Check that each module is

 

 

 

firmly installed in the MMAC.

 

 

 

Ensure that all connected ports

 

 

 

are enabled.

 

 

 

 