APPENDIX A: EMM-E6 SPECIFICATIONS

 

Table A-2. EPIM-F3 Statistics

 

Parameter

Typical

Minimum

Maximum

Transmitter Peak

1300 nm

1270 nm

1330 nm

Wave Length:

 

 

 

Spectral Width:

60 nm

100 nm

Rise Time:

3.0 ns

2.7 ns

5.0 ns

Fall Time:

2.5 ns

2.2 ns

5.0 ns

Duty Cycle:

50.1%

49.6%

50.7%

TX Power:

-15.1 dBm

 

 

TX Budget:

14.4 dBm

 

 

RX Sensitivity:

-29.5 dBm

 

 

MAX Receive

-6.99 dBm

 

 

Power:

 

 

 

 

 

Bit Error Rate:

Better than 10-10

 

 

NOTE

The above transmitter power levels and receive sensitivity levels represent Peak Power Levels after optical overshoot. You must use a Peak Power Meter to correctly compare the above values to those you measure on any particular port. If you measure Power Levels with an Average Power Meter, you must subtract 3 dBm from the measurement to correctly compare those measured values to the values listed above (e.g., -29.5 dBm peak = -32.5 dBm average).