APPENDIX B: COMMONLY-USED OIDs

B.5 ACTIVATING RMON GROUPS

The initial configuration of the EMM-E6 at installation does not provide the activation of the RMON Default and Host Groups. These management groups may be activated or deactivated through local management using OID Sets. As the specific OID used to control each RMON bundle is dependent upon the presence or absence of BRIMs and their type, an SNMP Get is necessary to determine the OID instances of the RMON bundles before they may be enabled or disabled.

chCompName

Description: Returns OID values for the location of the RMON bundle OIDs in the device being examined. These values may be used in conjunction with the chCompAdminStatus OID (below) to activate and deactivate the individual RMON bundles.

Object Identifier:

1.3.6.1.4.1.52.4.1.1.2.4.1.5

Data Type:

Integer

Access Policy:

read-write

chCompAdminStatus

Description: Enables and disables the RMON Default Group for an EMM-E6.

Object Identifier:

[Result of above SNMP Get]

Data Type:

Integer

 

Values:

7

disable

 

3

enable

Access Policy:

read-write

 

B-10

EMM-E6 User's Guide

Page 182
Image 182
Cabletron Systems EMM-E6 Ethernet manual Activating Rmon Groups, ChCompName, ChCompAdminStatus