CHAPTER 11: DEVICE STATISTICS SCREEN

NETWORK

This command lets you select the network you want to monitor. The choices range from A to F, depending on the configuration of your network and the options available from this configuration. For example, if you do not have a Media Interface Module running on the A Channel, the EMM-E6 automatically disallows Channel A as a network selection.

SLOT

This command lets you select the MMAC hub slot that you want to monitor. The choices vary depending on the MMAC chassis you use. The far right slot is always slot number one (1).

PORT

This command lets you select and view port statistics for ports 1 through 26 of the device residing in the selected Slot.

11.2.1Selecting an Update Frequency

The EMM-E6 updates the Device Statistics screen every three seconds by default. The EMM-E6 allows you to adjust this frequency in intervals of three seconds (maximum frequency is 99 seconds).

To adjust the UPDATE-FREQ:

1.Use the arrow keys to highlight the UPDATE-FREQcommand.

2.Press the Shift and + keys together, or just the - key until the desired time/frequency appears (this number increments/decrements in 3 second intervals; minimum = 3 seconds; maximum = 99 seconds).

3.Press the Return key to set and save the changes to the UPDATE-FREQ field.

11-4

EMM-E6 User’s Guide