Cisco Systems SCE 2000 4/8xFE manual Troubleshooting the Management Subsystem

Models: SCE 2000 4/8xFE

1 131
Download 131 pages 39.66 Kb
Page 123
Image 123
Troubleshooting the Management Subsystem

Chapter 8 Troubleshooting

 

 

Problem Solving Using a Subsystems Approach

 

 

 

 

Symptom

Possible Cause

Possible Solution

 

 

 

 

Returned error is:

The package file does not exist in

Verify package file location and

Error—File <file

the specified location.

try again.

 

 

 

name> does not exist

 

 

 

In the output of the command,

Package file type mismatch.

Verify that you are trying to

the package file type is

 

open the correct package file.

management-image

 

 

 

instead of system-image

 

 

 

In the output of the command,

Package file platform mismatch.

Verify that you have the package

the package file platform is

 

file appropriate to your platform

not the correct installation file

 

type.

for the SCE 2000.

 

 

 

 

 

 

 

Returned error is:

The file is not a software

Verify that you are trying to

Package file <file

installation package file.

open the correct package file.

 

 

 

name> does not

 

 

 

contain magic header

 

 

 

Returned error is:

/tffs0/ device is full.

Delete old and unnecessary files

Error—There are only

 

and try the package extraction

 

again.

X free bytes on

 

 

 

device <device

 

 

 

name>, but Y bytes

 

 

 

are needed for the

 

 

 

extraction (where X

 

 

 

and Y are stated in

 

 

 

bytes)

 

 

 

Troubleshooting the Management Subsystem

Check the following to help isolate a problem in the management subsystem.

Problems in the management subsystem could be any of the following:

Management link is down. (Mng LINK LED not lit--also Status is WARNING)

Management link is up (Mng LINK LED lit) but does not answer ping

Telnet connection cannot be established due to link problems (Mng LINK LED not lit)

Management link is up (Mng LINK LED lit) but Telnet connection cannot be established

Telnet connection established, but terminates automatically

Note When the management link is down and/or a Telnet connection cannot be established, you must open a CLI session on a local terminal connected to the CON port. This enables you to solve the problem and then reconnect through the management port.

Cisco SCE 2000 4/8xFE Installation and Configuration Guide

 

OL-7826-05

8-11

 

 

 

Page 123
Image 123