Cisco Systems SCE 2000 4/8xFE manual Shutting Down the SCE Platform

Models: SCE 2000 4/8xFE

1 131
Download 131 pages 39.66 Kb
Page 111
Image 111
Shutting Down the SCE Platform

Chapter 7 Basic SCE 2000 Platform Operations

Rebooting and Shutting Down the SCE Platform

Shutting Down the SCE Platform

Shutting down the SCE platform is required before turning the power off. This helps to ensure that non-volatile memory devices in the SCE platform are properly flushed in an orderly manner.

Note When the SCE platform restarts, it loads the startup configuration, so all changes made in the running configuration will be lost. You are advised to save the running configuration before performing reload, as described in Saving the Configuration Settings (on page 7-5).

To shut down your SCE platform, complete the following steps:

Step 1 Connect to the serial console port (The CON connector on the SCE platform front panel, 9600 baud).

The SCE 2000# prompt appears. Step 2 Type reload shutdown.

A confirmation message appears.

Step 3 Type Y to confirm the shutdown request and press Enter.

EXAMPLE:

The following example shows the commands for system shutdown.

SCE 2000#reload shutdown

You are about to shut down the system.

The only way to resume system operation after this is to cycle the power off, and then back on. Continue?

y

IT IS NOW SAFE TO TURN THE POWER OFF.

Note Since the SCE platform can recover from the power-down state only by being physically turned off (or cycling the power), this command can only be executed from the serial CLI console. This limitation helps prevent situations in which a user issues this command from a Telnet session, and then realizes he/she has no physical access to the SCE platform.

Cisco SCE 2000 4/8xFE Installation and Configuration Guide

 

OL-7826-05

7-11

 

 

 

Page 111
Image 111
Cisco Systems SCE 2000 4/8xFE manual Shutting Down the SCE Platform, y IT IS NOW SAFE TO TURN THE POWER OFF