Chapter 4 Installation and Maintenance
Removing and Replacing a Power Supply Unit
Power Supply Specifications
The following table lists the AC-input and DC-input power supply specifications for the SCE
2000 platform:
Table 4-7 | SCE 2000 Power Supply Specifications |
| | |
AC-input power | | 200W maximum |
| |
AC-input voltage rating | 100 to 240 VAC |
| |
AC-input current rating | Rated for 4.5A when Vin = 100 VAC or 2A when Vin = 200 VAC |
| |
AC-input frequency rating | 50 to 60 Hz |
| | |
AC-input cable | | 18 AWG three-wire cable, with a three-lead IEC-320 receptacle on |
| | the power supply end, and a country-dependent plug on the power |
| | source end. |
| | |
DC-input power | | 200W maximum |
| |
DC-input voltage rating | –48/-60 VDC nominal (–36 to–72 VDC supply tolerance) |
| |
DC-input current rating | 7A at –48 VDC |
| | |
DC-input cable | | 12 AWG or 2.5-mm copper installation wire with hex or loop |
| | connectors |
| |
DC-input circuit breaker | One Fast 10A for each power supply unit |
| | |
Note For AC-input power, we recommend powering the SCE 2000 platform from a 120 VAC, 15A receptacle U.S. (240 VAC, 10A international) at the power source.
Removing and Replacing a Power Supply Unit
The procedures for removing and replacing the AC-input or DC-input power supply are explained in the following sections:
•Powering Down the Power Supply Unit and Disconnecting Input Power (on page 4-15)
•Removing the Power Supply Unit (on page 4-16)
•Replacing the Power Supply Unit (on page 4-17)
•Reconnecting the Power (on page 4-17)
ESD Warning Do not remove or install modules without using appropriate anti-static guard measures. The SCE 2000 includes an anti-static wrist strap in the accessory kit. Attach the copper tape strap to an unpainted metal surface on the chassis. You may leave the strap connected to the chassis when your have finished.
Cisco SCE 2000 4/8xFE Installation and Configuration Guide