Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration

Initial System Configuration

EXAMPLE 2:

Following is a sample topology configuration for a non-redundant inline topology. In this topology, a single SCE 2000 is connected to one or two FE links.

When the inline connection mode is specified, the user must specify the on-failure link behavior.

Would you like to enter the Topology configuration menu? [no]: y Enter Connection mode:

1- inline

2- receive-only

Enter your choice [1]: 1

Is this a cascade deployment? [no]: no Enter On-failure behavior:

1- bypass

2- cutoff

Enter your choice [1]: 1

Enter admin status of the SCE after abnormal boot:

1- Operational

2- Not-Operational

Enter your choice [1]: 1

Data collection for the system configuration is completed.

EXAMPLE 3:

Following is a sample topology configuration for a secondary SCE 2000 in a redundant inline topology. In this topology there are two SCE 2000s that are cascaded via the cascade FE ports (ports 3 and 4). Each SCE 2000 is connected inline to both sides (subscribers/network) of one FE link.

In this case, the user must specify the physically-connected-link index (link-0 in our example), the priority of the SCE 2000, and the on-failure link behavior.

Would you like to enter the Topology configuration menu? [no]: y Enter Connection mode:

1- inline

2- receive-only

Enter your choice [1]: 1

Is this a cascade deployment ? [no]: yes Enter Physically connected link:

0- link-0

1- link-1

Enter your choice [0]: 0 Enter SCE 2000 priority:

1- primary

2- secondary

Enter your choice [1]: 2 Enter On-failure behavior:

1- bypass

2- cutoff

Enter your choice [1]: 1

Enter admin status of the SCE after abnormal boot:

1- Operational

2- Not-Operational

Enter your choice [1]: 1

Data collection for the system configuration is completed.

Cisco SCE 2000 4/8xFE Installation and Configuration Guide

5-22

OL-7826-05

 

 

 

 

Page 80
Image 80
Cisco Systems SCE 2000 4/8xFE manual Example