Cisco Systems SCE 2000 4/8xFE manual Problem Solving Using a Subsystems Approach

Models: SCE 2000 4/8xFE

1 131
Download 131 pages 39.66 Kb
Page 120
Image 120
Problem Solving Using a Subsystems Approach

Chapter 8 Troubleshooting

Problem Solving Using a Subsystems Approach

SCE 2000

Description

Status LED State

Operational

 

 

Status

 

 

 

 

 

Warning

SCE 2000 is fully operational (as above) but one of the

Flashing orange

 

following occurred:

 

 

• Line ports (FE ports) to the link are down

 

 

• Management port link is down

 

 

• Temperature raised above threshold

 

 

• Voltage not in required range

 

 

• Fans problem

 

 

• Power supply problem

 

 

• Insufficient space on the disk

 

 

Note: If the condition that caused the SCE 2000 to be in

 

 

Warning state is resolved (for example, link is up) the SCE

 

 

2000 reverts to Operational state.

 

 

 

 

Failure

System is in Failure state after Boot due to one of the following

Red

 

conditions:

 

 

• Power on test failure

 

 

• Three abnormal reboots in less than 20 minutes

 

 

• Platform configured to enter Failure mode consequent to

 

 

failure-induced reboot (this is configurable using CLI

 

 

command)

 

 

Note: Depending on the cause of failure, the management

 

 

interface and the platform configuration may or may not be

 

 

active/available.

 

 

 

 

Problem Solving Using a Subsystems Approach

Identifying Startup Problems

Startup problems are commonly due to the source power or to a poor cable connection.

When you start up the SCE 2000 platform for the first time, you should observe the startup sequence described in the Starting the SCE 2000 Platform (on page 7-1). This section contains a more detailed description of the normal startup sequence and describes the steps to take if the system does not perform that sequence as expected. LEDs indicate all system states in the startup sequence. By checking the state of the LEDs, you can determine when and where the system failed in the startup sequence. Use the following descriptions to isolate the problem to a subsystem, and then proceed to the appropriate sections to try to resolve the problem.

When you start up the system by turning on the power supply switch, the following should occur:

You should immediately hear the fans operating.

Cisco SCE 2000 4/8xFE Installation and Configuration Guide

8-8

OL-7826-05

 

 

 

 

Page 120
Image 120