Cisco Systems SCE 2000 4/8xFE manual Replacing the Fan Module, 17 Inserting the Fan Module

Models: SCE 2000 4/8xFE

1 131
Download 131 pages 39.66 Kb
Page 57
Image 57
Replacing the Fan Module

Chapter 4 Installation and Maintenance

Fan Module Overview Figure 4-17: Inserting the Fan Module

To remove the fan module, complete the following steps:

Step 1 Using a 1/4-inch flat-blade screwdriver, loosen the two captive screws on the faceplate of the fan module.

Step 2 Grasp the fan module handle and remove it from the router.

This completes the procedure for removing the fan module from a SCE 2000 platform.

Replacing the Fan Module

To install a new fan module into a SCE 2000 platform, complete the following steps:

Step 1 Grasp the fan module handle with one hand and place your other hand underneath the fan module for support. The handle of the unit should be at the bottom.

Step 2 Fit the groove in the side of the new fan module into the guide in the chassis.

Step 3 Gently, but firmly, slide the module into the chassis until its faceplate is flush with the chassis rear panel.

Figure 4-17: Inserting the Fan Module

Warning When inserting a fan module into the SCE 2000 platform, do not use unnecessary force; slamming the fan module into the chassis can damage the connectors on the rear of the module.

Step 4 Seat the fan module in the SCE 2000 platform by tightening the two captive installation screws with a 1/4-inch flat-blade screwdriver.

Note The fan module is not fully seated until you tighten the installation screws on the faceplate.

This completes the procedures for replacing a fan module in a SCE 2000 platform.

Cisco SCE 2000 4/8xFE Installation and Configuration Guide

 

OL-7826-05

4-21

 

 

 

Page 57
Image 57
Cisco Systems SCE 2000 4/8xFE manual Replacing the Fan Module, 17 Inserting the Fan Module