Chapter 4 Installation and Maintenance
Fan Module Overview
Step 8 Ensure that the power supply is properly aligned and the installation screw is tightened.
This completes the steps for reconnecting the
Fan Module Overview
The fan module provides cooling for the internal components. The fan drawer is a field- replaceable unit containing five fans, and is installed at the right rear of the SCE 2000 platform.
When a fan malfunctions, the fan module should be replaced as promptly as possible. Although it is possible for the unit to function for some time with one
Figure 4-16: SCE Platform Fan Module
When a fan failure occurs, the environment monitor will send an error message to the console. An SNMP trap indicating that the fan is not functioning properly is also sent. Note that a fan failure is often audible.
Removing and Replacing the Fan Module
The following sections explain how to remove and replace a fan module in a SCE 2000 platform:
•Removing the Fan Module (on page 4-20)
•Replacing the Fan Module (on page 4-21)
ESD Warning Do not remove or install modules without using appropriate
Removing the Fan Module
Warning When removing the fan drawer, keep hands and fingers away from the spinning fan blades. Let the fan blades stop completely before removing the fan drawer.
Cisco SCE 2000 4/8xFE Installation and Configuration Guide
| ||
|
|
|