Chapter 6 Cabling the Line Ports and Completing the Installation
Installing a Cascaded System
In packets discarded: 0
In packets with CRC/Alignment error: 0
In undersized packets: 0
In oversized packets: 0
Out total octets: 93*2^32+1022342538
Out unicast packets: 858086051
Out non unicast packets: 0
Out packets discarded: 0
You are now ready to continue to the next stage, loading and activating an Service Control application.
Installing a Cascaded System
This section outlines the installation procedures for a redundant solution with two cascaded SCE 2000s. Refer to the Cisco Service Control Engine (SCE) CLI Command Reference for details of the CLI commands.
Warning When working with two SCE 2000s with 
To install a cascaded system, complete the following steps:
Step 1 Install both SCE 2000s, power them up, and perform the initial system configuration. (See Installation and Maintenance (on page 
Step 2 Connect both SCE 2000s to the management station.(See Connecting the Management Interface (on page 
Step 3 Connect the cascade ports. The cascade ports must be connected directly in Layer 1 (dark fibers), not through switches. (See Dual Link: Two SCE 2000s Topology (on page 
Step 4 Set topology configurations for each SCE 2000 via the 
Step 5 Make sure that theSCE 2000s have synchronized and active SCE 2000 was elected.
Use the show interface linecard 0 connection-mode  command.
Step 6 If you want to start with bypass/sniffing, change the link mode to your required mode in both SCE 2000s on both links. The bypass mode will be applied only to the active SCE 2000. (See Link Mode (on page 
Step 7 Make sure that the link mode is as you required. (See Monitoring the System (on page 
Use the show interface linecard 0 link mode command.
Step 8 Connect the traffic port of SCE 2000 #1. This will cause a momentary down time until the network elements from both sides of the SCE 2000 
Cisco SCE 2000 4/8xFE Installation and Configuration Guide
  | ||
  | 
  | 
  |