Chapter 3 Installing the CiscoWorks 1130 Wireless LAN Solution Engine
Installing the CiscoWorks 1130 Wireless LAN Solution Engine
–Other countries: If local and national electrical codes are not available, see IEC 364, Part 1 through Part 7.
•Do not work alone under potentially hazardous conditions.
•Do not perform any action that creates a potential hazard to people or makes the equipment unsafe.
•Do not attempt to install the WLSE into a rack that has not been securely anchored in place. Damage to the system and personal injury may result.
•Due to the size and weight of the computer system, never attempt to install the computer system by yourself.
See Precautions for
Warning To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety:
This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack. Statement 1006
To install the WLSE in a rack, perform the following steps:
Step 1 In the
Note The
| Installation and Configuration Guide for the CiscoWorks Wireless LAN Solution Engine |