Chapter 6 Troubleshooting
Troubleshooting the Installation and Setup
Table
Table |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
Switch | Name |
| Description | Default | Baud Rate Select |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| BR1 | BR0 | Rate |
|
|
|
|
|
|
|
|
1 |
| Not used | OFF | 0 | 0 | 9600 | |
|
|
|
|
|
|
|
|
2 |
| Not used | OFF | 1 | 0 | 19200 | |
|
|
|
|
|
|
|
|
3 | BR1 |
| Baud rate select | OFF | 0 | 1 | 38400 |
|
|
|
|
|
|
|
|
4 | BR0 |
| Baud rate select | OFF | 1 | 1 | 57600 |
|
|
|
|
|
|
|
|
Table |
| SW3— System Configuration |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
Switch | Name |
| Description | Default | Memory Select | Load Sequence Override | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MR1 | MR2 | Description | LS1 | LS2 | Description |
|
|
|
|
|
|
|
|
|
|
|
1 | MS1 |
| Memory | OFF | 0 | 0 | Normal | 0 | 0 | Normal sequence |
|
|
| select |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 | MS2 |
| Memory | OFF | 1 | 0 | External ROM card | 1 | 0 | Run ROMMON with WDOG |
|
|
| select |
|
|
|
|
|
| disabled |
|
|
|
|
|
|
|
|
|
|
|
3 | LS2 |
| Load | OFF | 0 | 1 | Emulation mode | 0 | 1 | Run SysLoader |
|
|
| sequence |
|
|
| (reserved) |
|
|
|
|
|
| override |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 | LS1 |
| Load | OFF | 1 | 1 | Emulation mode | 1 | 1 | Normal sequence with WDOG |
|
|
| sequence |
|
|
| (reserved) |
|
| disabled |
|
|
| override |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Table |
|
|
|
|
| ||
|
|
|
|
|
|
| |||
|
| Switch | Name | Description | Default | ||||
|
|
|
|
|
| ||||
1 | CTST | OFF | |||||||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| ||||
2 | RXDT | OFF | |||||||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| ||||
3 | RTSS | OFF | |||||||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| ||||
4 | MODE | Serial Port Mode | OFF | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| Cisco |
|
|
| ||
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|