Chapter 5 Cabling the RF Switch With the Cisco uBR7246VXR CMTS
Installing the Header Blocks on the Cisco uBR 3x10 RF Switch
Installing the Header Blocks on the Cisco uBR 3x10 RF Switch
This section describes attaching the header blocks to the RF switch.
The RF cables are connected to the CMTS, PROTECT, and CABLE PLANT portions of the
Cisco uBR 3x10 RF Switch using the header blocks. Header blocks are installed on the RF switch at the following locations:
•
•
•CABLE
Equipment
•36 header blocks
•
To install header blocks, complete the following steps.
Step 1 With the beveled edge of the header block at the top, line up the two alignment pins on the header block with the two holes corresponding to the RF connector group under the CMTS, PROTECT, or CABLE PLANT section of the Cisco uBR 3x10 RF Switch.
Step 2 Press the header block into place, using equal pressure on both the upper and lower portions of the header block.
Step 3 Use a
Note Tighten the header blocks to the Cisco uBR 3x10 RF Switch only after gently pulling on the cables to be sure that they are firmly seated in the header block.
Caution Do not overtighten the captive screws. We recommend that you tighten the screws to 5 to 7
Figure
Alignment pins
Header Block Description
Header block (top)
Bevel
Screws
MCX | 95808 | |
connectors | ||
|
Cisco
|
| ||
|
|