Chapter 5 Cabling the RF Switch With the Cisco uBR7246VXR CMTS

Installing the Header Blocks on the Cisco uBR 3x10 RF Switch

Installing the Header Blocks on the Cisco uBR 3x10 RF Switch

This section describes attaching the header blocks to the RF switch.

The RF cables are connected to the CMTS, PROTECT, and CABLE PLANT portions of the

Cisco uBR 3x10 RF Switch using the header blocks. Header blocks are installed on the RF switch at the following locations:

CMTS—RF cables connect to working cable interface line cards and to IF-to-RF upconverters.

PROTECT—RF cables connect to protecting cable interface line cards

CABLE PLANT—RF cables connect to the cable headend or hub.

Equipment

36 header blocks

Flat-blade screwdriver

To install header blocks, complete the following steps.

Step 1 With the beveled edge of the header block at the top, line up the two alignment pins on the header block with the two holes corresponding to the RF connector group under the CMTS, PROTECT, or CABLE PLANT section of the Cisco uBR 3x10 RF Switch.

Step 2 Press the header block into place, using equal pressure on both the upper and lower portions of the header block.

Step 3 Use a flat-blade screwdriver to tighten the captive installation screws at both the top and bottom of the header block to prevent accidental disconnections.

Note Tighten the header blocks to the Cisco uBR 3x10 RF Switch only after gently pulling on the cables to be sure that they are firmly seated in the header block.

Caution Do not overtighten the captive screws. We recommend that you tighten the screws to 5 to 7 inch-pounds (0.5647 to 0.7909 nm)

Figure 5-5

Alignment pins

Header Block Description

Header block (top)

Bevel

Screws

MCX

95808

connectors

 

Cisco uBR-3x10 RF Switch Hardware Installation and Cabling Guide

 

OL-1984-06

5-7

 

 

 