SAFETY INFORMATION

This unit operates under Safety Extra Low Voltage (SELV) conditions according to IEC 950. The conditions are only maintained if the equipment to which it is connected also operates under SELV conditions.

The appliance coupler (the connector to the unit and not the wall plug) must have a configuration for mating with an EN60320/IEC320 appliance inlet.

France and Peru only

This unit cannot be powered from IT† supplies. If your supplies are of IT type, this unit must be powered by 230V (2P+T) via an isolation transformer ratio 1:1, with the secondary connection point labeled Neutral, connected directly to ground.

POWER CORD

This must be approved for the country where it is used:

USA and The cord set must be UL-approved and CSA-

Canada certified.

The minimum specification for the flexible cord is No. 18 AWG, Type SV or SJ, 3-conductor.

The cord set must have a rated current capacity of at least 10A.

The attachment plug must be an earth-grounding type with a NEMA 5-15P (15A, 125V) or NEMA 6-15P (15A, 250V) configuration.

Denmark The supply plug must comply with section 107-2-D1, standard DK2-1a or DK2-5a.

Switzerland The supply plug must comply with SEV/ASE 1011.

If the power cord plug is unsuitable and must be replaced, you may find other codings for the respective connections. Connect the power supply wires for the unit according to the following scheme:

Brown wire to the Live (Line) plug terminal, which may be marked with the letter “L” or colored red.

Blue wire to the Neutral plug terminal, which may be marked with the letter “N” or colored black.

Yellow/Green wire to the Ground plug terminal, which may be marked with the

letter “E” or the Earth symbol or colored yellow/green.

A-2