Appendix A:

Environmental specifications

The following specifications identify maximum environmental conditions. At no time should the server run under conditions which violate these specifications.

Variable

Requirements

Temperature

Maximum rate of change: 18°F (10°C) per hour

 

Nonoperating: -55° to 150°F (-48.3° to 65.5°C)

 

Operating: 41° to 95°F (5° to 35°C); derated 0.9°F (0.5°C) for every

 

1,000 feet (305 meters). Use of 2 GB DIMMs derates the server to

 

86°F (30°C)

Altitude

10,000 feet (3,048 meters) maximum

Humidity

Operating wet bulb: Not to exceed 91.4°F (33 °C) (with diskette drive

 

or hard drive)

 

Nonoperating: 95% relative (noncondensing) at 86° F (30° C)

116

www.gateway.com

Page 122
Image 122
Gateway 955 manual Environmental specifications, Variable Requirements