Chapter 6: Troubleshooting
The diskette drive LED is lit continuously
■Remove the diskette from the drive. If the light stays on, try restarting your server.
■Turn off your server, then remove the combination drive and push it in again to make sure the drive is seated correctly. For instructions, see “Replacing the CD/diskette drive in the Flex Bay” on page 49.
Expansion cards
Your server does not recognize an expansion card
■Restart your server.
■Make sure that you have installed the necessary software or driver. For instructions, see the card’s documentation.
■Reseat the expansion card and the riser card. For instructions, see “Installing PCI expansion cards” on page 60.
Hard drive
The hard drive cannot be accessed, or you receive a “General failure reading drive C” error message
■If a diskette is in the diskette drive, eject it and restart your server by pressing the reset button.
■Restart your server by pressing the reset button.
■Turn off your server, then remove all hard drives and push them in again to make sure the drives are seated correctly. For instructions, see “Installing a hard drive” on page 54.
■Run a verification from the SCSI BIOS.
■If your server has been subjected to static electricity or physical shock, you may need to reinstall the operating system.
You receive a “Non-system disk” or “disk error” error message
■Eject the diskette from the diskette drive, then press ENTER.
■Make sure that your hard drive has an active partition. For more information, see “The master boot record is corrupted” on page 107.
106 | www.gateway.com |