Click Save to save the changes.
Click Close to return to the PEM window.

Chapter 3: Maintaining Your Server

Setting up paging alerts

To set up paging alerts:

1 Boot your server from the Server Companion CD, then select System Setup Utility from the menu. The System Setup Utility starts.

2 Install an external modem on the serial RJ-45 port on the back of your server.

3 In the SSU Main window, click Platform Event Manager (PEM).

4 In the PEM window, click Configure EMP.

5 In the corresponding boxes, enter the following command strings for the modem attached to the serial RJ-45 port:

ESC Sequence—The escape sequence. This string is sent to the modem before sending command strings. The maximum length for the string is five characters. Longer strings are truncated.

Hangup String—Hang up or drop the connection. The EMP automatically sends an ENTER character following this string. The maximum length for the string is eight characters.

Modem Dial Command—The command to dial a phone number. This string is sent to the modem before sending the paging string.

Modem Init String—Initialization string for the modem. Sent every time the EMP initializes. You will be notified if the string is truncated. Following a save, the actual string saved is displayed in the edit box.

6

7

8 In the PEM window, click Configure PEP.

9 Click to select the Enable PEP check box.

10 In the Blackout Period box, type the minimum time, in minutes, between successive pages. The valid range is 0-255 where 0 disables the blackout period.

Setting a blackout period can save you from being flooded with repeat pages. After you receive a PEP page, no additional pages are sent by PEP for the duration of the blackout period.

40

www.gateway.com

Page 46
Image 46
Gateway 955 manual To set up paging alerts