Power supply system

Ac/dc power distribution

The ac line voltage for the printer is applied through the main switch (SW101) and supplied to the low-voltage power supply circuit through the fuse (F1). The low-voltage power supply divides the ac voltage to +24 Vdc, +5 Vdc and +3.4 Vdc and supplies them to the dc controller PCA. This circuit generates a zero-cross signal (ZEROX) and supplies it to the dc controller PCA.

+3.4 Vdc is supplied to ICs on the formatter, the dc controller PCA, and the BD PCA. +5 Vdc

￿is supplied to the laser driver PCA and sensors.

+24 Vdc is supplied to the high-voltage power supply circuitry on the dc controller, driving the

￿main motor, the exhaust fan, the scanner motor, the clutches, and the solenoids.

+24 Vdc is divided into +24 Vdr, which stops when the top cover is opened and SW401 on

￿the paper-handling PCA turns off, and +24 V, which is always supplied regardless of whether SW401 turns on or off.

Figure 10.Low-voltage power supply circuit

72 Functional information

Q1860-90918

www.GovTechMedia.com