| SCPI COMMAND SUMMARY |
|
|
MARKer[n]:MODE | How the frequency of the marker is determined. |
FREQuency | Absolute frequency is used. The limits are |
| confined to the present START and STOP |
| frequency limits. |
DELTa | The value is specified with respect to the |
| reference marker. (MARKer[n]:REFerence) |
|
|
The *RST values are the same as the FREQ : CENTcommand *RST value.
•MARKer EnI : MODE FREQuency I DELTa
•MARKer [n] : MODE?
Sets and queries the mode of the specified marker. Setting one marker to delta turns all other marker modes to frequency. If [n] is not specified, the default is one. *RST value is FREQuency.
•MARKer [n] : REFerence <r-r>
•MARKer [nl : REFerence?
Sets and queries which marker is the reference marker for use in the delta mode. While [n] may be used, there is really only a single reference for all the markers. MARKerl :REFerence 5; and MARKer2:REFerence 5; both set marker 5 as the reference.
•MARKer [n] [ : STATeI ON OFF 1 O
•MARKer [n] [ : STATe] ?
The state of the specified marker is set and queried (marker number one if [n] is not specified). The *RST value for all markers is OFF.
•MEASure : AM?
A
a MEASure : FM
A
•MODulation:OUTPut:SOURceAMIFM
•MODulation:OUTPut:SOURce?
Sets and queries the source of the rear panel output modulation
BNC.
•MODulation:OUTPut:STATe ONlOFFlllO
•MODulation:OUTPut:STATe?
Sets and queries the state of the rear panel output modulation BNC.
HP 8360 | Operating and Programming Reference |