Step Swp PtTrig Ext

Function Group

Menu Map

Description

Programming Codes

FREQUENCY

2

When this softkey is selected, the synthesizer steps to the next point in the stepped frequency sweep when an external hardware trigger is received. When the last frequency point is reached and continuous sweep is selected, the next trigger causes the step sweep to return to the start frequency. Connect the trigger signal to the TRIGGER INPUT BNC. An asterisk next to the key label indicates that this feature is active.

SCPI: SWEep:TRIGger:SOURce EXT

Analyzer: TS

See Also Step Swp Menu, Sweep Mode Step

“Using Step Sweep,” in Chapter 1.

(STOP)

Function Group

Menu Map

Description

Programming Codes

FREQUENCY

NONE

This softkey activates swept frequency mode and makes the stop frequency parameter the active function. The start/stop frequency must be separated by at least 2 Hz in order to remain in the frequency sweep mode. If start=stop frequency then the zero span mode is entered.

SCPI:

FREQuency:STOP <num>[freq suffix] or

MAXimum]MINimum]UP]DOWN

FREQuency:MODE:SWEep

Analyzer: FB <num> [HzIKz~MzIGz]

HP 8360

Operating and Programming Reference S-71