S t e p S w p P t

Trig Auto

Function Group

Menu Map

Description

FREQUENCY

2

When this softkey is selected, the synthesizer automatically steps to the next point in the stepped frequency sweep until all points are swept. The time between points is equal to the sum of the dwell and phase lock times. An asterisk next to the key label indicates that this feature is active.

Programming Codes SCPI: SWEep:TRIGger:SOURce IMMediate

Analyzer: NONE

See Also Step Swp Menu, Sweep Mode Step

“Using Step Sweep,” in Chapter 1.

st;ep S w p Pt

Trig Bus

Function Group

Menu Map

Description

FREQUENCY

2

When this softkey is selected, the synthesizer steps to the next point in a stepped frequency sweep when an HP-IB trigger

(*TRG, <GET>) is received (leading edge TTL). When the last frequency point is reached and continuous sweep is selected, the next trigger causes the step sweep to return to the start frequency. Connect the trigger signal to the TRIGGER INPUT BNC. An asterisk next to the key label indicates this feature is active.

Programming Codes SCPI: SWEep:TRIGger:SOURce BUS

Analyzer: TS

See Also Step Swp Menu, Sweep Mode Step

S-70 Operating and Programming Reference

HP 8360

User’s

Handbook

Page 368
Image 368
HP 8360 manual Trig Auto, Trig Bus