Lucent Technologies 555-661-150 manual Programmed on This System Switch Identifiers

Models: 555-661-150

1 360
Download 360 pages 28.58 Kb
Page 151
Image 151

Table 2–24. Scenario 5: Facilities Planning, Calls Originating within the Private Network and Going to the PSTN

 

System A: Atlanta, GA

System O: Atlanta, GA

System N: Denver, CO

Component

(Area Code: 404)

(Area Code: 404)

(Area Code: 303)

 

 

 

 

DS1 Switch Type

Private Network

MERLIN LEGEND-Ntwk

MERLIN LEGEND-Ntwk

Programmed on

 

 

 

this System

 

 

 

 

 

 

 

Switch Identifiers

Not applicable

51 for a system that is within 200 miles

41 for a system that is more than 200

Programmed on

 

and is not a MERLIN LEGEND

miles away and is not a MERLIN

This System

 

Communications System (System A)

LEGEND Communications System

 

 

 

(System A)

 

 

 

 

ARS Access Codes

9

9

9

 

 

 

 

 

DEFINITY ECS or DEFINITY ProLogix

All programmable routes (Default

Area Code Tables specify routing to

ARS Routing: Calls Solutions system manager

Local, Default Toll, Dial 0 tables)

PRI tandem trunk pools connected to

to Local or Nearby

determines appropriate restrictions.

specify the main pool of tandem PRI

System A for calls to other Colorado

Area Codes

 

trunks.The Special Numbers Table

area codes as well as to more distant

 

routes emergency calls to the correct

area codes.

 

 

local services and also routes IXC calls through System A. All ARS tables must prepend a 9 (ARS access code).

2 Call-Handling Scenarios Network Configuration Scenarios

MERLIN LEGEND Communications Network Reference 555-661-150

 

System Release 6.1

ARS Routing: Calls to Distant Area Codes

No calls are routed through other systems, even calls to the 303 (Denver, CO) area code.

All routing specifies the main pool, 70, where all tandem PRI facilities are connected. FRLs are adjusted according to the cost of the call and the job requirements of the user.

To reach customers, agent outcalls are routed to PSTN PRI B-channels connected to System A, which subscribes to OUTWATS services for this purpose. The FRL for these routes is 2.

*DEFINITY ECS and DEFINITY ProLogix Solutions systems do not have a Switch Type setting. The Interface field on such a system identifies the type of the DEFINITY ECS or DEFINITY ProLogix Solutions system, not the type at the other end of the tandem trunk as on MERLIN LEGEND Communications Systems. If the Interface field specifies Network, as it typically might, the MERLIN LEGEND Communications Systems specify MERLIN LEGEND-Ntwk. If the Interface field specifies User, the MERLIN LEGEND Communications Systems are programmed with the MERLIN LEGEND-PBX setting.

Page2-93

Issue 1 August 1998

Page 151
Image 151
Lucent Technologies 555-661-150 manual Programmed on This System Switch Identifiers