Table 2–3.

Scenario 1: ARS Routing Summary, Calls Originating within the private network and Going to the PSTN

 

 

 

 

 

 

 

 

 

 

 

 

 

System A: New York, NY (Area Code: 212)

 

 

 

System B: Holmdel, NJ (Area Code: 732)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dialed or Rec’d

 

 

 

 

 

Dialed or Rec’d

 

 

 

 

 

 

Digits￿￿￿￿￿

 

Rte

Pool Type

Abs

Prep

FRL

Digits

Rte

Pool Type

Abs

Prep

FRL

 

 

 

 

 

 

 

 

￿￿￿￿￿

 

 

 

 

 

 

 

 

1

Tandem

0

9

0

 

1

Tandem

0

9

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Local PSTN

0

0

1

 

2

Local PSTN

0

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

 

All

Local PSTN

4

0

0

 

All

Local PSTN

4

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Tandem

0

9

1

 

1

Tandem

0

9

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

 

2

Local PSTN

0

0

2

 

2

Local PSTN

0

0

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All

Local PSTN

0

0

2

￿￿￿￿￿

All

Local PSTN

0

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rte = Sample route number (1= preferred routes; 2=secondary routes) Prep = Prepended (prefixed) digits

Abs = Number of absorbed (deleted) digits

FRL= ARS Facility Restriction Level. For calls from the private network tandem

 

trunks, it is compared to default COR for the type of tandem trunk. For

 

local system calls (including remote access calls) it is compared to the

 

extension or barrier code FRL of the caller.

 

 

 