MERLIN LEGEND Communications System Release 6.1

Issue 1

Network Reference 555-661-150

August 1998

6 Troubleshooting

 

Call to Non-Local Extension: Silence or Fast Busy Tone

Page 6-10

 

 

select the 3ULQW option on the System Programming menu and then choose￿35,￿,QIR.￿“PRI Facilities Switch Type” on page 23 provides summary instructions for determining the switch type programmed at your system and changing it if necessary. “Switch Type” in the Chapter 4 “PRI Facilities” section of System Programming gives full details.

In Release 6.1 and later systems, the PRI Switch Type Test requests the system at the other end to verify that the correct PRI switch type is programmed. This test should be run only by Lucent Technologies technicians or authorized representatives.

If the call is carried over other systems connected by tandem PRI facilities, the coordinating system manger must ensure that the settings are correct, as in this example of MERLIN LEGEND Communications Systems:

System A LEGEND-PBXSystem B LEGEND-NtwkSystem C LEGEND-PBX

If the switch type settings are correct and problem persists, do one of the following:

— If the call is a data call, go to Possible Cause 8.

— If the call is not a data call, call the Lucent Technologies Helpline at 1 800 628-2888; consultation charges may apply.

Possible Cause 8: The FRL for the default COR for tie trunks (T1-emulated voice or data, or analog) on the remote system may be blocking tandem calls. The private network includes at least one analog tie trunk.

What to Do: Check with the coordinating system manager so that he or she can determine where the problem exists. This may involve more than one system, depending upon how your private network is set up. For example, a call might be routed across the private network in a fashion such as this:

Origin System ASystem BSystem CDestination System D

In this configuration, the coordinating system manager must check routes and default COR attributes for Systems B and C.

Check to make sure the calling restriction of the default COR is set to unrestricted. The factory setting is outward restricted, which blocks calls across the private network.

Check that the routes voice/data capability is correct for the type of call being made. The factory setting is Both. Routes need to be programmed for voice or data, but not both.

If the call is routed over the PSTN, check ARS routes including the default local and non-local routes to be sure that the setting is either voice or data, but not both.

In each intervening system, compare the FRLs assigned to routes for the call with the default COR FRL. The route FRL must be equal to or lower than the default COR value or the call is blocked. The factory setting is 3.