MERLIN LEGEND Communications System Release 6.1

Issue 1

Network Reference 555-661-150

August 1998

C Voice/Fax Messaging Systems

 

 

Supported System Considerations

Page C-3

 

 

 

 

Messaging 2000

3

 

 

 

All local and non-local UDP extensions must be programmed as mailboxes.

Messaging 200 can handle 2- 3- or 4-digit dial plans but not simultaneously. All MERLIN LEGEND systems sharing the Messaging 2000 must be renumbered to the same number of digits in the dial plan.

IS-III AUDIX Voice Power

3

Existing AUDIX Voice Power systems can be used for centralized VMS/AA, but this system can no longer be ordered.

The AUDIX Voice Power Directory consists of the local UDP extensions (“Subscribers”) and the non-local UDP numbers (“Special Extensions”). This directory should not exceed 300 entries (maximum number of mailboxes). When the dialed number does not match one of the numbers in the Directory, the attempt to transfer the call is denied.

When using analog tandem tie trunks as private network facilities, each remote (non-local UDP) station must be added to the AUDIX Voice Power Directory’s database with Class of Service set to Custom and Switch Call Coverage set to Yes. Otherwise, the transfer will fail unconditionally.

When using T1 tie and/or PRI tandem trunks as private network facilities, each local UDP station must be added to the database, but the Class of Service setting and the Switch Call Coverage setting do not affect operation. The maximum number of rings (0-9) is not required with Switch Call Coverage, but is required when no Switch Call Coverage is specified.

Page 313
Image 313
Lucent Technologies 555-661-150 manual Messaging, IS-III Audix Voice Power