The Copy Telephone Number to Send setting is set to Copy for the PRI tandem trunk B-channel group; this setting cannot be changed as long as the switch type is in effect. For more information, see “Copy Telephone Number to Send” in the “PRI Facilities” section of System Programming.

DEFINITY ECS and DEFINITY ProLogix Solutions systems use the Interface field to specify the equivalent of a switch type. It identifies a slot on the local system as Network or User. User is the usual setting. If the Interface field specifies Network, the MERLIN LEGEND Communications Systems slot specifies LEGEND-Ntwk. If the Interface field specifies User, the MERLIN LEGEND Communications Systems specifies LEGEND-PBX. DEFINITY ECS and DEFINITY ProLogix Solutions system documentation provides details about the Interface field.

Task List: Switch Type

5

oObtain Form 3b, Incoming Trunks: DS1 Connectivity (100D module).

oRead Chapter 2, “Call-Handling Scenarios,” to see examples showing Switch Type settings for different private network configurations.

oPlan changed or new switch types using the planning guidelines above and after consulting other system managers in the private network. Record the new values on the form.

oOpen the System Programming menu from the console or a PC with SPM.

oProgram the change(s), following the instructions below or those for “Switch Type” in the “PRI Facilities” section of System Programming, or the summary programming instructions below.

oWhen you have finished, file the form with the rest of the planning forms.

Programming Instructions

Console Procedure

PC Procedure

5

/LQHV7UXQNV35,6ZLWFK7\SHDial slot no.(QWHUSpecify switch type(QWHU([LW([LW

￿￿￿Type slot no.￿Specify switch type ￿￿￿

Page 220