MERLIN LEGEND Communications System Release 6.1 | Issue 1 | |
Network Reference | August 1998 | |
5 Network Management |
| |
| Tandem PRI Facilities | Page |
|
|
|
| PRI Facilities Switch Type | 5 |
|
|
|
In this procedure, two additional switch types allow you to specify additional switch options in order to set up a PRI tandem trunk that connects two MERLIN LEGEND Communications Systems or a MERLIN LEGEND Communications System and a DEFINITY ECS or DEFINITY ProLogix Solutions system. The two additional options are the following:
■MERLIN LEGEND Communications System Networked:
■MERLIN LEGEND Communications System PBX:
Planning Guidelines | 5 |
To set up a PRI tandem trunk, one system is specified as operating in PBX mode and the other as operating in network mode. When you program this switch type, you specify the type of switch at the other end of the PRI trunk, not the local switch. The slot number that you enter is the slot number on the local system.
In Release 6.1 and later systems, the PRI Switch Type Test requests the system at the other end to respond with information about the PRI Switch Type specification. Lucent Technologies technicians or authorized representatives can run this test to determine the PRI Switch Type at the other end.
The following rules apply to PRI tandem trunks in PBX or network mode:
■A single unused
■PRI
■PRI outgoing call tables do not apply to outgoing calls on the PRI tandem trunk.
■The system automatically assigns Electronic Tandem Network (ETN) as the network service for the