Maintenance Object Repair Procedures
Page10-63ANL-16-L (16-Port Neon Analog Line)
10
0NO
BOARD The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board i s inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-es tablish the
linkage between the internal ID and the port. If this is not the case,
dispatch to check to ensure that there is a valid board inserted.