DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-515DIOD-TRK (DIOD Trunk) [G1.2SE]
10
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. These are in-line errors that have no specific test associated with them.
Refer to the following table for an explanation and appropriate action.
b. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate associ ated
errors (if any).
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2. Minor alarms on this MO may be downgraded to warning alarms based on the values used in the
set options command. If the Minor alarm is not downgraded by the set-options val ues, th e Minor
alarm is upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
DIOD Trunk Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear
Value
010 Any Any A ny test port
PCSSpp sh r
1
15 (b) any Port Audit Update Test
(#36)
18 0 busyout trunk
<grp>/<mbr>
769 (a) 57392 None MAJ/MIN/
WRN2ON
1537 Dial Tone Test (#0) MAJ/MIN/
WRN2ON test port
PCSS l r 2
1793 Loop Around and
Conference Test (#33) MAJ/MIN/
WRN2ON test port
PCSS l r 3
2049 NPE Cross Talk Test (#6) MAJ/MIN/
WRN2ON test port
PCSS l r 3
2561 (a,d) 57345 None
2817 (a,e) 57393 No ne
3073 (a,c) 57376 No ne
3073 (a,c) 57424 No ne
3585 (a,c) 57424 No ne