DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page8-77clear isdn-test call
8
If the cabinet and carrier is invalid for a PPN, the following message is displayed:
Invalid port-network s pecified
If the carrier is not a valid carrier, the following message is displayed:
Invalid carrier specified
If the technician-entered carrier is not active, the following message is displayed:
Board invalid
If there is not a PI circuit pack administered for the specified position, but the
specified carrier is active, the following error message is displayed:
Processor Interface (T N765) not started or i s being started
If the command entered is in conflict with another currently executing command,
then a message is displayed showing the login id of the conflicting user and the
conflicting command. The message is as follows:
’login id’:’command’ h as a command conflict
If, during the execution of a command, a resource problem occurs that requires
the user to restart the command, then the following message is displayed:
Command resources busy ; Press CANCEL to clea r, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message is displayed:
All maintenance resources busy; try again later
Output
If the clear interface command is successful, the following message is displayed
on the SAT:
Command successfully c ompleted
If the clear interface command is unsuccessful, the following message is
displayed on the SAT:
Error encountered, ca n’t complete request
Feature Intera c tions
None.
clear isdn-testcall
This command cancels a ISDN-PRI test call already in progress.