DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-446DID-TRK (DID Trunk)
10
Hardware Error Log Entries and Test to Clear
Values
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set
options command. If the Minor alarm is not downgraded by the set-options values, the Minor alarm is
upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
DID Trunk Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
010 Any Any Any test port PCSSpp sh r 1
1 (a) Any None WRN OFF
1 (b) 57476 None WRN O FF
1 (c) 57477 None WRN OFF
1 (d) 57483 None WRN O FF
15 (e) Any P ort Audit Update
(#36)
18 0 busyout trunk
<grp/mbr> WRN OFF release trunk <grp/mbr>
130 (f) None WRN O N test trunk <grp>/<mbr>
257 (g) 57472 None WRN OFF
257 (h) 57473 None W RN OFF
257 (i) 57474 None WRN O FF
257 (j) 57475 None WRN O FF
513 (k) 57392 None MAJ/MIN/
WRN2OFF
510 (l) 57393 None
769 Any Port Diagnostic
(#35) MAJ/MIN/
WRN2ON test port PCSSpp r 3
1025 Loo p Around and
Conference (#33) MAJ/MIN/
WRN2ON test port PCSSpp r 3
1281 NPE Crosstalk (#6) MAJ/MIN/
WRN2ON test port PCSSpp r 3
1537 Any Port Diagnostic
(#35) MAJ/MIN/
WRN2OFF test port PCSSpp r 3
1793 (m) 57489 None None