DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-493DIG-LINE (Digital Line)
10
Table 10-133. TEST #16 DIG-LINE Station Lamp Updates Test
Error
Code Test
Result Description/ Recommendation
ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
1 ABORT This port may have been busied out by system
technician.
1. Look in the Error Log for Error Type 18 (port busied
out) for this port. If t h i s e rr o r t ype is present, then
release the port via the release station
<extension> command and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum
of 5 times.
4. If the test continues to abort, escalate the problem.
3 ABORT Station may be in ready-for-service or out-of-service
state.
1. Use status station command to verify state of
station.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals a maximum
of 5 times.
4. If the test continues to abort, escalate the problem.
Continued on next page